Tlačiť

Hľadali ste: SMCC (N-Succinimidyl 4-(N-Maleimidomethyl)cyclohexanecarboxylate)


5  results were found

SearchResultCount:"5"

Sort Results

Zobraziť zoznam Easy View (Nové)

Ohodnotiť tieto výsledky vyhľadávania

Katalógové číslo: (BC20)
Dodávateľ: G BIOSCIENCES
Opis: Succinimidyl 4-(N-maleimidomethyl) cyclohexane-1-carboxylate Heterobifunctional Cross Linkers.
Merná jednotka: 1 * 100 mg


Dodávateľ: Apollo Scientific
Opis: Primary amine and Sulphhydryl reactive, Enzyme antibody conjugation.

Nové řešení transparentnosti pro evropské zákazníky

Všimli jste si naší nově zlepšené viditelnosti rozmístění zásob u pokladny?

Zjistěte více

Zlepšení rozmístění zásob

Dodávateľ: AAT BIOQUEST
Opis: SMCC is a non-cleavable and membrane permeable crosslinker with a spacer arm of 8.3 Å. It contains an amine-reactive succinimidyl ester (SE) and a sulfhydryl-reactive maleimide group. NHS esters react with primary amines at pH 7 to 9 to form stable amide bonds. Maleimides react with sulfhydryl groups at pH 6.5 to 7.5 to form stable thioether bonds. The SE group of SMCC is reacted with lysine residues on the carrier protein, converting them to reactive maleimides. SMCC is a reagent that is widely used for generating stable maleimide-activated carrier proteins that can spontaneously react with sulfhydryls. Alternatively these relatively stable maleimide-activated intermediates may be lyophilized and stored for later conjugation to a hapten.

Katalógové číslo: (PIERA35394)
Dodávateľ: Thermo Fisher Scientific
Opis: Thermo Scientific Pierce SMCC is a hetero-bifunctional crosslinker that contain N-hydroxysuccinimide (NHS) ester and maleimide groups that allow covalent conjugation of amine- and sulfhydryl-containing molecules. NHS esters react with primary amines at pH 7–9 to form amide bonds, while maleimides react with sulfhydryl groups at pH 6.5–7.5 to form stable thioether bonds. In aqueous solutions, NHS ester hydrolytic degradation is a competing reaction whose rate increases with pH. The maleimide group is more stable than the NHS-ester group, but will slowly hydrolyze and lose its reaction specificity for sulfhydryls at pH values > 7.5. For these reasons, conjugations with these crosslinkers are usually performed at pH 7.2–7.5, with the NHS ester (amine-targeted) reacted before or simultaneous with the maleimide (sulfhydryl-targeted) reaction.
Merná jednotka: 1 * 10 mg


Katalógové číslo: (PIER22360)
Dodávateľ: Thermo Fisher Scientific
Opis: Thermo Scientific Pierce SMCC is a hetero-bifunctional crosslinker that contain N-hydroxysuccinimide (NHS) ester and maleimide groups that allow covalent conjugation of amine- and sulfhydryl-containing molecules. NHS esters react with primary amines at pH 7–9 to form amide bonds, while maleimides react with sulfhydryl groups at pH 6.5–7.5 to form stable thioether bonds. In aqueous solutions, NHS ester hydrolytic degradation is a competing reaction whose rate increases with pH. The maleimide group is more stable than the NHS-ester group, but will slowly hydrolyze and lose its reaction specificity for sulfhydryls at pH values > 7.5. For these reasons, conjugations with these crosslinkers are usually performed at pH 7.2–7.5, with the NHS ester (amine-targeted) reacted before or simultaneous with the maleimide (sulfhydryl-targeted) reaction.
Merná jednotka: 1 * 50 mg

Zavolať a opýtať sa na ceny
Zásoby tejto položky sú obmedzené, no môžu sa nachádzať v inom sklade blízko pri vás. Uistite sa prosím, že ste prihlásený/á na tejto lokalite, aby sa mohli zobraziť dostupné zásoby. Ak sa stále zobrazuje zavolajte a potrebujete pomoc, zavolajte nám prosím na číslo +43 1 97002 - 0.
Zásoby tejto položky sú obmedzené, no môžu sa nachádzať v inom sklade blízko pri vás. Uistite sa prosím, že ste prihlásený/á na tejto lokalite, aby sa mohli zobraziť dostupné zásoby. Ak sa stále zobrazuje zavolajte a potrebujete pomoc, zavolajte nám prosím na číslo +43 1 97002 - 0.
Daná chemikália je regulovaná podľa platnej legislatívy a bude vyžadované vyplnenie formulára. Jeho včasným vyplnením urýchlite dodanie produktu.
-Na zakúpenie tejto položky môže byť potrebná dodatočná dokumentácia. Ak to bude potrebné, skontaktuje sa s vami zástupca spoločnosti VWR.
Tento produkt bol zablokovaný vašou organizáciou. Kontaktujte prosím vaše oddelenie nákupu pre získanie viac informácií.
Pôvodný produkt už nie je dostupný. Je dostupná zobrazená náhrada.
Tento produkt už nie je dostupný. Môžu byť k dispozícii alternatívy, ktoré sa dajú vyhľadať pomocou katalógového čísla VWR uvedeného vyššie. Ak potrebujete ďalšiu pomoc, zavolajte prosím na zákaznícky servis spoločnosti VWR na čísle +43 1 97002 - 0.
1 - 5 of 5
no targeter for Bottom