Loop sterilizers are designed to sterilize metal inoculating loops and needles without using an open flame. With an electric heat source, these devices eliminate any hazards common with gas and open flames making the environment safer for personnel. The features prevent infectious spatter and cross-contamination. Infrared sterilization methods are ideal for use in anaerobic chambers. Loop sterilizers also can disinfect other non-sharp laboratory tools such as pipettes and other glass instruments used in quality control or research.

Loop sterilizers are designed to sterilize metal inoculating loops and needles without using an open flame. With an electric heat source, these devices eliminate any hazards common with gas and open flames making the environment safer for personnel. The features prevent infectious spatter and cross-contamination. Infrared sterilization methods are ideal for use in anaerobic chambers. Loop sterilizers also can disinfect other non-sharp laboratory tools such as pipettes and other glass instruments used in quality control or research.


7  results were found

SearchResultCount:"7"

Sort Results

Zobraziť zoznam Easy View (Nové)

Ohodnotiť tieto výsledky vyhľadávania

Katalógové číslo: (710-1475)
Dodávateľ: BioTool
Opis: Infrared sterilisation system which is suitable for sterilising loops, needles and micro instruments. Ideal for use in laboratories where using gases or naked flames is not permitted. The specifically focused infrared light generates an IR hot spot. The unit with its quartz glass tube, is instantly ready for use and does not require any warm up time. Thermocontrol facilitates minimum heat dissipation and ensures efficient use of power, meaning low energy consumption when unit is not in use.
Merná jednotka: 1 * 1 items


Dodávateľ: BioTool
Opis: Electrical sterilisation systems which are suitable for sterilising loops, needles and instruments. Ideal for use in laboratories where using gases or naked flames is not permitted. The e-Loop has a wear resistant quartz glass tube which is protected by a perforated stainless steel outer design. Choice of two units with different tube diameters, the larger is ideal for sterilising small instruments such as forceps and scissors. The heating system provides uniform heat. The opening eliminates the potential aerosol of pathogenic microorganisms.

Nové řešení transparentnosti pro evropské zákazníky

Všimli jste si naší nově zlepšené viditelnosti rozmístění zásob u pokladny?

Zjistěte více

Zlepšení rozmístění zásob

Dodávateľ: HAMILTON BONADUZ
Opis: Specifically designed for rapidly cleaning 7000 series modified Microliter™ syringes, this syringe cleaner also effectively cleans Microliter™ and Gastight® syringes. A combination of heat (approximately 370 °C) and vacuum vaporises and extracts contaminants from the needle. The syringe cleaner is ineffective for septa-plugged needles, seised plungers and other irreparable needles.

Dodávateľ: WARTEWIG
Opis: Infrared loop sterilisers provide annealing without the risks of flames. The SteriMax electrical sterilisation system is ideal for sterilising inoculation loops, needles or instruments, for use in laboratories and safety cabinets where the use of gases or open flames is not permitted.

Katalógové číslo: (WART4.001.000)
Dodávateľ: WARTEWIG
Opis: SteriMax smart is made of stainless steel and safety glass with a touch panel and thus offers many advantages even for extreme laboratory conditions.
Merná jednotka: 1 * 1 items


Katalógové číslo: (WART4.101.000)
Dodávateľ: WARTEWIG
Opis: The <i>SteriMax basic</i> infrared loop steriliser provides high speed annealing and sterilising without a flame.
Merná jednotka: 1 * 1 items


Katalógové číslo: (SCUT3399002)
Dodávateľ: SCHUTT LABORTECHNIK
Opis: The Schuett Solaris is the perfect solution to avoid using naked flames or if gas cartridges are not available. The unit uses standard electrical power and reaches the safe working temperature of 900 to 1300 °C within seconds. No warm-up time, no excess heat, no energy consumption between work cycles. Start is generated by an infra-red sensor, which allows efficient one-handed operation. The integrated timer can be set to 5 or 7 s. Pathogenic material is kept inside the sterilisation chamber. No spreading, no sooting. Ideal for use in Laminar Flow Cabinets. Working angle can be adjusted. Robust and sturdy, no parts subject to mechanical wear, ideal for mobile operation in the field.
Merná jednotka: 1 * 1 items


Zavolať a opýtať sa na ceny
Zásoby tejto položky sú obmedzené, no môžu sa nachádzať v inom sklade blízko pri vás. Uistite sa prosím, že ste prihlásený/á na tejto lokalite, aby sa mohli zobraziť dostupné zásoby. Ak sa stále zobrazuje zavolajte a potrebujete pomoc, zavolajte nám prosím na číslo +43 1 97002 - 0.
Zásoby tejto položky sú obmedzené, no môžu sa nachádzať v inom sklade blízko pri vás. Uistite sa prosím, že ste prihlásený/á na tejto lokalite, aby sa mohli zobraziť dostupné zásoby. Ak sa stále zobrazuje zavolajte a potrebujete pomoc, zavolajte nám prosím na číslo +43 1 97002 - 0.
Daná chemikália je regulovaná podľa platnej legislatívy a bude vyžadované vyplnenie formulára. Jeho včasným vyplnením urýchlite dodanie produktu.
-Na zakúpenie tejto položky môže byť potrebná dodatočná dokumentácia. Ak to bude potrebné, skontaktuje sa s vami zástupca spoločnosti VWR.
Tento produkt bol zablokovaný vašou organizáciou. Kontaktujte prosím vaše oddelenie nákupu pre získanie viac informácií.
Pôvodný produkt už nie je dostupný. Je dostupná zobrazená náhrada.
Tento produkt už nie je dostupný. Môžu byť k dispozícii alternatívy, ktoré sa dajú vyhľadať pomocou katalógového čísla VWR uvedeného vyššie. Ak potrebujete ďalšiu pomoc, zavolajte prosím na zákaznícky servis spoločnosti VWR na čísle +43 1 97002 - 0.
1 - 7 of 7
no targeter for Bottom